Professional Online 2000VA, 1930W UPS - TAA
UPC: 881317519535
Choose options
Reliable Power Back Up for All IT Equipment Needs
IOGEAR Online UPS Battery Back Up GBB2000N – 2000VA/1930 Watts is a high-performance UPS system with NEMA 5-20P input plug and 8 NEMA 5-20R outlets designed for most server rack configurations that support data, network and communication applications. It utilizes true double conversion with 96% power factor efficiency for all the power supplied by the UPS for critical IT equipment needs and output voltage regulation provides higher performance for critical applications. The rackmount form factor installs use only two rack spaces (2U). It ships with all mounting accessories for a four-post rackmount installation.
Online UPS Battery Design
IOGEAR Online UPS design utilizes true double conversion with 96% power factor efficiency over industry & competitor standards for all the power supplied by the UPS for critical server needs and output voltage regulation provides higher performance for critical applications.
Expandable Power Configurations
IOGEAR Online UPS provides expandable power solutions with External Battery Packs that can be daisy chained to increase system runtime.
Programmable Power Management Outlets
During a power failure, this feature enables users to extend battery time to mission-critical devices by shutting down noncritical applications and devices.
Emergency Power Off function
EPO connector at rear panel allows emergency UPS Power Off from a remote location.
SNMP + USB + RS-232 Multiple Communications
Use either USB or RS-232 communication ports to work with SNMP interface simultaneously.
Swappable Battery Design
IOGEAR Online UPS Battery Back Up swappable battery design allows for complete power module exchange without powering down connected equipment.
Efficient Power Modes
IOGEAR Online UPS batteries use ECO Mode to conserve energy and allow up to 97% efficiency cutting energy usage and cost. The unit provides over-voltage cut-off protection and surge immunity by MOV for full-time equipment protection. The Online UPS battery high power factor charging up to 1930W capacity with very low ripple current when charging the battery. The smart battery charger design allows the Online UPS to optimize battery performance by adjusting charging voltage according to outside temperatures and extends the useful service life of batteries.
Multi-Functional LCD Interface
IOGEAR Online UPS features multi-function LCD interfaces for displaying detailed information on input voltage, battery capacity, power status, battery status, operating status, assessed backup runtime and more for IT system administrators.
Add an External Battery Pack for Extended Runtime
Extend runtime on critical systems with a 48V External Battery Pack (GBP48V18AH), a high-performance expandable rackmount external battery pack solution for the Online UPS Battery Back Up GBB2000N. The external battery pack provides extended battery runtime for critical server rack configurations that support data, communication and network applications. An included daisy chain connector to enable the connection of additional compatible 48V external battery packs to primary Online UPS Battery Back Up system.
Note: When any online ups battery and extendable battery pack, provided or purchased separately, is not in use, recharge it for 4 ~ 6 hours every 3 ~ 6 months.
- True double-conversion – Output power factor is 0.96, which means all of the power supplied is being used for productive work and makes work the most efficient.
- Output voltage regulation < 1% – Provides higher performance and efficiency for critical applications.
- Pure sine wave output - Provides clean power source to your sensitive and mission critical equipement, such as IT, Medical, Telcom, to keep the great performance and prevent unexpected shutdown and damage.
- Programmable power management outlets – Users can easily and independently control load segments. During power failure, this feature enables users to extend battery time to mission-critical devices by shutting down noncritical devices.
- Emergency Power Off function (EPO) – EPO connector at rear panel allows emergency UPS Power Off from a remote location.
- SNMP + USB + RS-232 multiple communications – Allows either USB or RS-232 communication ports to work with SNMP interface simultaneously.
- Hot swappable battery design – All potential UPS maintenance, including complete power module exchange, can be performed without powering down connected equipment. As long as utility power is on, you can leave the UPS and connected equipment on while replacing the battery.
- ECO mode for energy saving – Offers up to 97% efficiency to cut energy usage and cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.
- Provides over-voltage cut-off protection and surge immunity by MOV for full-time equipment protection.
- High power factor charger up to 1000W capacity with very low ripple current when charging battery.
- Multi-functional LCD interface – Displays immediate, detailed information on input voltage, battery capacity, power status, battery status, operating status, and assessed backup runtime, etc.
- Smart battery charger design to optimize battery performance – Adjusts charging voltage according to outside temperatures and extends the useful service life of batteries.
Source Outlet Type - NEMA 5-20R
Device Plug Type- NEMA 5-20P
- 1 x Online UPS - GBB2000N
- 1 x Rack Mounting Kit Set
- 4 x Tower Stand
- 1 x Rail Slide Kit Set
- 1 x RS-232 Cable
- 1 x USB Type-A to B Cable
- 1 x User Manual
Need more help with this product? Visit IOGEAR Knowledge Base
Function | GBB2000N |
---|---|
UPS Topology | On-Line (Double Conversion) |
Energy Saving | >96%(ECO), >90%(AC), >89%(Batt) |
Network Interface | SNAP Card |
Input | |
Voltage | 100/110/115/120V |
Voltage Range | 80-150 VAC ± 5%@ 100% load, 55-150 VAC ± 5%@ 50% load, Derate capacity to 80% when the output voltage is adjusted to 100VAC |
Frequency Range | 40 Hz ~ 70 Hz |
Cold Start | Yes |
Plug Type | NEMA 5-20P |
Power Factor | ≧ 0.99 @ nominal voltage (100% load) |
Cord Length | 6 ft. |
Output | |
Volt Amp Capacity (VA) | 2000 |
Output Watt Capacity (Watts) | 1930 |
Rated Power Factor | 0.96 |
On Battery Waveform | Sine Wave |
On Battery Frequency | 50/60Hz +/- 3 Hz |
Outlets | 8 |
Outlet Types - Battery & Surge Protected | 8 x NEMA 5-20R |
Crest Factor | 3:1 |
Harmonic Distortion | ≦ 2 % THDv(Linear Load), ≦ 4 % THDv (Non-linear Load) |
Voltage Regulation | ± 1%(Batt) |
Transfer Time (AC to Battery) | 0ms |
Transfer Time (Inverter to Bypass) | 4ms(ECO) |
Battery | |
Runtime at Half Load (min) | 10.0 |
Runtime at Full Load (min) | 2.95 |
Battery Type | Sealed Lead-Acid |
Battery Pack Voltage | 48V |
Battery Quantity | 4 |
Hot-Swappable | Yes |
Typical Recharge Time | 3 hours recover to 95% capacity @2A charging current., Max charger current 8A |
Extended Battery Module | GBP48V18AH |
Environment | |
Operation Temperature | 0 ? 40 °C(32 ? 104 °F) |
Storage Temperature | -20 ? 50 °C(-4 ? 122 °F) |
Humidity | 20-90% RH / 10% to 95% (no condensing) |
Certification | UL FCC |
Dimensions | GBB2000N |
---|---|
Unit Dimensions | |
Height | 3.5 in. (8.9 cm) |
Length | 20 in. (50.8 cm) |
Width | 17.3 in. (44 cm) |
Master Carton | |
Height | 9.75 in. (24.8 cm) |
Length | 27.75 in. (70.5 cm) |
Width | 22 in. (55.9 cm) |
Master Carton Qty. | 1 |
Weight | |
Master Carton Wt. | 56.1 lb. (25.5kg) |
Unit Wt. | 46.5 lb. (21.1 kg) |